Research Line Scan Confocal Microscope L Series

Research Line Scan Confocal Microscope L Series,Standard wavelength 405±5nm/488nm±5nm/561nm±1nm/640nm±5nm,Laser power adjust accuracy:0.1%, Multi-wavelength AOTF adjustment power,Single wavelength output power:>20mW,Power stability:<1%,Spectrum Linewidth<3nm

MODEL:Research Line Scan Confocal Microscope L Series

6-10 Weeks Drawings

Save To My List

* The prices are indicative only. Please contact us for an official quote. This is single product page, for detail specification please refer to product main page


Compare Model Drawings & Specs Availability Reference Price
Industry Line Scan Confocal Microscope
Industry Line Scan Confocal Microscope,Standart wavelength:405nm±5nm,Output way:Single-mode polarization-maintaining fiber coupling (TEM00),Single wavelength output power:>20mW,Power stability:<1%,Spectrum Linewidth<3nm
In Stock Request for quote
Automated Fluorescence Microscope
Automatic fluorescence microscope,can be selected as an upright or inverted microscope, customer-customized
In Stock Request for quote
SIMSCOP Raman S2
SIMSCOP Confocal/PL Raman Microscope , Multi-channel laser up to 5 channels, wavelengths 405nm/532nm/638nm/785nm/1064nm, Laser power 100mW, linewidth 0.001nm, Near-infrared spectrum support, Raman range typical 150~3200cm-1, Confocal image resolution ~200nm @100x objective, Electric continuously variable speed pinhole mode, spot size ~1um@50x, Compatible with upright/inverted microscopes, Compatible with standard stretching stages, high/low-temperature stages, in-situ stages, and vacuum stages
6-8 weeks Request for quote
SIMSCOP Raman S1
SIMSCOP Confocal/PL Raman Microscope , Single-channel laser, wavelengths 532nm/638nm/785nm optional, Laser power 100mW, linewidth 0.003nm, Raman range typical 150~3200cm-1, Confocal image resolution ~200nm @100x objective, manual pinhole mode, spot size ~1um@50x, Compatible with upright/inverted microscopes,Compatible with standard stretching stages, high/low-temperature stages, in-situ stages, and vacuum stages
6-8 weeks Request for quote
DermDive
Wideband Handheld Confocal Raman Skin Analyzer, Detection Range: FP: 450 – 1750cm-1; HW: 2800-3750cm-1, Axial Resolution: 10um~20um, Sensitivity: 60dB, Scanning Time: 2-10s/depth
6-8 Weeks Request for quote
SpinDisk SIM
Structured Illumination Microscope, SIM Basic, Image frame rate 13fps@1024x1024, Resolution ~100nm, image depth <50um, No. of Laser - 4, Wavelength choice 405/445/470/520/528/555/640nm, sCMOS Camera detectors, Inverted or upright microscope, XYZ motorized stages, Motorized filter electronics system, high image contrast, upgrade to SpinDisk SIM 100nm resolution
6-10 Weeks Request for quote
SIM Basic
Structured Illumination Microscope, SIM Basic, Image frame rate 13fps@1024x1024, Resolution ~100nm, image depth <50um, No. of Laser - 4, Wavelength choice 405/445/470/520/528/555/640nm, sCMOS Camera detectors, Inverted or upright microscope, XYZ motorized stages, Motorized filter electronics system, high image contrast, upgrade to SpinDisk SIM 100nm resolution
6-10 Weeks Request for quote
SpinDisk Advance
Spinning Disk Confocal Microscope, SpinDisk Advance Series, Image frame rate 100fps@2048x2048, Resolution ~230nm, image depth <200um, No. of Laser - 4, Wavelength choice 405/445/470/520/528/555/640nm, Dual sCMOS Camera detectors (single sCOMS optional), Inverted or upright microscope, XYZ motorized stages, Motorized filter electronics system, high image contrast, upgrade to SpinDisk SIM 100nm resolution, customized option
6-10 Weeks Request for quote
SpinDisk Basic Spinning Disk Confocal Microscope
Spinning Disk Confocal Microscope, SpinDisk Basic Series, Image frame rate 100fps@2048x2048, Resolution ~230nm, image depth <200um, No. of Laser - 4, Wavelength choice 405/445/488/525/561/640nm, sCMOS Camera detectors, Inverted or upright microscope, XYZ motorized stages, high image contrast, customized option
6-10 Weeks Request for quote
MIC-PL(XXX)
Fluorescence/Photoluminescence Microscope (System), Detector Hamamatsu area array back-illuminated CCD, cooling temperature -15 °C 6M Camera ,3072x2048, pixel size 2.4um. Spot size up to the diffraction limit (1um @50x objective lens @532nm). 3D dynamic scanning or 2D dynamic scanning optional.
4-6weeks Request for quote
SIMSCOP P Series
Laser Scanning Confocal Microscope, Standard Wavelength 405/488/561/640nm(638nm), dual-axis XY high-speed optical scanning galvanometer, field of view 15x15mm, scanning pixels 512x512 ~4096x4096, scan speed up to 4fps, stroke: X-110mm, Y-75mm, Z-9mm
In Stock Request for quote

Compatible

Compare Model Drawings & Specs Availability Reference Price

Product specifications

Parameter L Series Research
  Laser unit Standard wavelength405±5 nm/488nm±5nm/561nm±1nm/640nm±5nm
Output way
single-mode polarization-maintaining fiber coupling (TEM00)
Single wavelength output power
:>20mW
Power stability
<1%
Spectrum Linewidth
3nm
TTL Modulation
1kHz
Laser power adjust accuracy
0.1% Multi-wavelength AOTF adjustment power
Note
Available multi-wavelength: 375nm/445nm/473nm/515nm/525nm/532nm/ 633nm/660nm/685nm/785nm/808nm
  Detector BSI Line array scan camera Resolution4640x256
Pixel Size
5umx5um;
Wavelength
200nm-1100nm
Pixel bit depth
8/10/12bit
TDI Stage 64/128/192/256;
Line frequency
2 x 2 Binning: 257kHz;
3 x 3 Binning: 225kHz;
4 x 4 Binning: 200kHz;
  Scanning module Scanning pixel100 x 100 ~ 2048 x 2048
Frame rate
50fps(1024x1024pixels)
500fps(1024x100pixels) fast scanning module 
  XY resolution Standard scanning module230nm@100x Oil objective
Deep scanning module
150nm-200nm
  Imaging depth Standard scanning module< 100um
Deep scanning module< 600um
  FOV 5x1mmx1mm | 10x0.51mmx0.51mm | 20x0.26mmx0.26mm |
40x
0.13mmx0.13mm | 60x85umx85um | 100x51umx51um
  Electric filter module 4 sets
DAPI EM 445nm/50nm
FITC EM 530nm/50nm
TRITC EM 605nm/60nm
Cy5 EM 695nm/40nm
  Objective WF10X/23 Flat objectiveHigh eyepoint; collimating telescope
  Objective tube 45° tilt, pupil distance adjustment 50-75mm, adjustable visibility
  Objective swither Five-hole internal positioning converter; ball bearing internal positioning
  Sample stage MutualFixed stage 240mm×260mmTravel range135mm×85mm
Electric
Minimum stepl50nm; Repeatibility±0.1um;
Largest speed
≥100mm/s    Stage size≥270x170mm
Effective travel
X:1100mm Y:75mm   Largest load:>1KGhorizontal
  Z axis driver Confocal resolution/Minimum step0.05μm, Repeatibility+/-0.2μm,Maximum step 10mm
  Confocal module Coarse and fine coaxial adjustment with limit and locking devices; low-position coaxial focusing handwheel; fine adjustment increment of 1 μm
  Transmission lighting system Warm light LED with continuously adjustable brightness.LED knob brightness controller.
Condenser: ultra-long working distance of 72 mm, numerical aperture NA=0.30, with three-hole phase contrast ring plate
  Epifluorescence illumination system Multi-wavelength LED light source MG-100
6-position fluorescence module
Ultraviolet(U)EX:375/30nmDM:415EM:460/50nm
Blue(B)EX:475/30nm
DM:505EM:530/40nm
Yellow(Y)EX:540/25nm
DM:565EM:605/55nm
Red(R)EX:620/50nm
DM:655EM:692/45nm
  Software function Multicolor fluorescence localization processing, Z-stack data processing, large image stitching, image analysis, imaging data management, 3D imaging rendering

Industry Line Scan Confocal Microscope - Parameter

Automated Fluorescence Microscope  - Parameter

SIMSCOP Raman S2 - Parameter

SIMSCOP Raman S1 - Parameter

DermDive - Parameter

SpinDisk SIM - Parameter

SIM Basic - Parameter

SpinDisk Advance - Parameter

SpinDisk Basic Spinning Disk Confocal Microscope - Parameter

Research Line Scan Confocal Microscope L Series - Parameter

MIC-PL(XXX) - Parameter

SIMSCOP P Series - Parameter

Industry Line Scan Confocal Microscope - Download

Automated Fluorescence Microscope  - Download

SIMSCOP Raman S2 - Download

SIMSCOP Raman S1 - Download

DermDive - Download

SpinDisk SIM - Download

SIM Basic - Download

SpinDisk Advance - Download

SpinDisk Basic Spinning Disk Confocal Microscope - Download

Research Line Scan Confocal Microscope L Series - Download

MIC-PL(XXX) - Download

SIMSCOP P Series - Download