Scintillator Probe, Application Voltage 0~+1250V, PMT Diameter 3", Effective Size of Scintillator Φ75×75mm, Interface Type BNC SHV, Energy Resolution ≤8.5%,

MODEL:STM3113

6-8 weeks Drawings

Save To My List

* The prices are indicative only. Please contact us for an official quote. This is single product page, for detail specification please refer to product main page


Compare Model Drawings & Specs Availability Reference Price
STM3023
Nal Scintillator Detector, Input Voltage +11.5~+12.5V, Max.Input Current 50mA, Effective Size of Scintillator Φ75×75mm, Output Signal Polarity Negative, Output Signal Amplitude 1V, Output Signal Amplitude 6V, Energy Resolution ≤8.5%
6-8 weeks Request for quote
STM3022
Nal Scintillator Detector, Input Voltage +11.5~+12.5V, Max.Input Current 50mA, Effective Size of Scintillator Φ50×50mm, Output Signal Polarity Negative, Output Signal Amplitude 1V, Output Signal Amplitude 6V, Energy Resolution ≤8.5%
6-8 weeks Request for quote
STM3021
Nal Scintillator Detector, Input Voltage +11.5~+12.5V, Max.Input Current 50mA, Effective Size of Scintillator Φ25×25mm, Output Signal Polarity Negative, Output Signal Amplitude 1V, Output Signal Amplitude 6V, Energy Resolution ≤8.5%
6-8 weeks Request for quote
STM3112
Scintillator Probe, Application Voltage 0~+1250V, PMT Diameter 2", Effective Size of Scintillator Φ50×50mm, Interface Type BNC SHV, Energy Resolution ≤8.5%,
6-8 weeks Request for quote
STM3111
Scintillator Probe, Application Voltage 0~+1250V, PMT Diameter 1", Effective Size of Scintillator Φ25×25mm, Interface Type BNC SHV, Energy Resolution ≤8.5%,
6-8 weeks Request for quote

Compatible

Compare Model Drawings & Specs Availability Reference Price

Product Specifications

 Model STM3111 STM3112 STM3113 Unit
 Image


/
 Application Voltage 0~+1250 V
 PMT Diameter
1 2 3 Inch
 Applicable to the PMT STN2013 STN4021 STN2032 /
 Effective Size of Scintillator Φ25×25 Φ50×50 Φ75×75 mm
 Interface Type BNCSHV /
 Energy Resolution(1) ≤8.5 %
Work Environment Temperature 0~+40
Humidity ≤90%RH /
Storage Environment Temperature -20~+50
Humidity ≤93%RH /
 Test Ambient Temperature 25 /

Note:(1)The output state of the detector is adjusted by using 137Cs radioactive source test. 

STM3023 - Parameter

Type
Nal Scintillator Detector

STM3022 - Parameter

Type
Nal Scintillator Detector

STM3021 - Parameter

Type
Nal Scintillator Detector

STM3113 - Parameter

Type
Scintillator Probe

STM3112 - Parameter

Type
Scintillator Probe

STM3111 - Parameter

Type
Scintillator Probe

STM3023 - Download

STM3022 - Download

STM3021 - Download

STM3113 - Download

STM3112 - Download

STM3111 - Download