PG Series High Resolution Spectrometers

高分辨光谱仪.jpgThe PG Series is designed for specialised high resolution and ultra high resolution applications

PG4000-C5 - Ultra High Resolution (UV-VIS-NIR)

The PG4000-C5 series consists of 5 individual spectrometers separating the UV-VIS-NIR spectrum offering ultra high resolution of ~0.15nm fwhm across the entire spectrum. The individual spectrometers and wavlength ranges can be selected and integrated to provide seamless scanning quality over the entire spectrum. The compartmentalised options allows users to pick the spectrum they need - providing an economical service.



PG4000-C3 - Ultra High Resolution UV-VIS 

The PG4000-C3 series consists of 3 individual spectrometers separating the UV-VIS spectrum. The first set of wavelength ranges offer ultra high resolution of ~0.15nm fwhm across the UV VIS spectrum. The PG4003 series stretches into the NIR range, providing optical resolutions of 0.43nm.  The individual spectrometers can be integrated to provide seamless scanning quality over the entire spectrum. The compartmentalised options allows uers to pick the spectrum they need - providing an economical service.

Check the Specifications and Model Guide tab for more information.


✈International Shipping Available, Based in Singapore. 


Wavelength, Slit and Optical Resolution Specifications

Model Guide PG4000-C5 Series

Model

Wavelength Range (nm)

Wavelength   Exposure per Pixel (nm)

(Total pixel count: 3648)

Slit Width (um)

10um

25um

50um

100um

200um

Optical Resolution FWHM (nm) ±20% S.D.

PG4000-C5-1

180-400

0.06

0.21

0.24

0.4

0.79

1.6

PG4000-C5-2

395-602

0.06

0.2

0.24

0.39

 0.81

1.58

PG4000-C5-3

597-788

0.05

0.15

0.21

0.39

0.77

1.57

PG4000-C5-4

783-955

0.05

0.15

0.22

0.38

0.75

1.5

PG4000-C5-5

950-1100

0.04

0.14

0.21

0.35

0.68

1.36

 

Model Guide PG4000-C3 Series  

Model

Wavelength Range (nm)

Wavelength   Exposure per Pixel (nm)

(Total pixel count: 3648)

Slit Width (um)

10um

25um

50um

100um

200um

Optical Resolution FWHM (nm) ±20% S.D.

PG4000-C3-1

277-491

0.06

0.06

0.21

0.25

0.4

0.8

PG4000-C3-2

486-685

0.06

0.05

0.19

0.25

0.38

0.79

PG4000-C3-3

680-1100

0.05

0.12

0.43

0.53

0.79

1.58



PG2000 Specification Sheet 

Optical Specifications

Model Wavelength Range

200~1100nm

Optical Resolution

Refer to table

Integration Time

4ms ~ 60s

Grating

Refer to table

Slit Width

Refer to table

Dynamic Range

2000:1

SNR

3000:1 when Saturated

Correction Linearity

>99%

Optical platform:

Incident focal length   100mm, f-number 4.5, cross CT

Detector

Model

Toshiba, TCD1304DG

Pixel

3648

Dimensions

Size

157 x 115 x 41 mm³

Weight

          0.81 kg

Connection

Fiber Interface

SMA905

A/D Resolution

16 bits

Data Transmission

USB-B (square port), support USB2.0   communication protocol, 480Mbps transmission speed

Additional Function   Port

30 pin extended function port, support     breakout-board external function expansion board

External Trigger

4 modes: Normal / Level / Edge /   Synchronisation



Automatic Quotation Generation (Recommended)

To generate an automatic quotation request please login using the Sign In button (top right of the screen). 

New users will be given the opportunity to register. Join our mailing list and follow us on linkedin for constant updates.


Technical Assistance and Email Quotations (Recommended for Custom Orders, inquiries)

For technical assistance, custom orders or email quotations, drop us an email at info@simtrum.com.

We will get back to you within 3 working days.


Local Same Day Service

SINGAPORE: For same day service, please contact us at 6996 0391. Office Hours: 9am - 6pm (+8GMT)

For more contact information click here.


International Inquiries

SIMTRUM provides worldwide shipping and inquiry management. Please contact us for more information.


Wavelength (nm)


Search Reset
Compare Model Drawings & Specs Wavelength (nm) 25um Slit Optical Resolution (nm) 50um Slit Optical Resolution (nm) Availability Price
(USD)
PG4000-5C-395-602
Ultra High Resolution Spectrometer, Slit= 25um, Resolution: 0.12, Detection Range: 680-1100nm
395-6020.240.39 In Stock Request for quote
PG4000-5C-597-788
Ultra High Resolution Spectrometer, Slit= 25um, Resolution: 0.05, Detection Range: 486-685nm
597-7880.210.39 In Stock Request for quote
PG4000-5C-783-955
Ultra High Resolution Spectrometer, Slit= 25um, Resolution: 0.06, Detection Range: 277-491nm
783-9550.220.38 In Stock Request for quote
PG4000-5C-950-1100
Ultra High Resolution Spectrometer, Slit= 25um, Resolution: 0.04, Detection Range: 950-1100nm
950-11000.210.35 In Stock Request for quote
PG4000-3C-277-491
Ultra High Resolution Spectrometer, Slit= 25um, Resolution: 0.05, Detection Range: 783-955nm
277-4910.210.25 In Stock Request for quote
PG4000-3C-486-685
Ultra High Resolution Spectrometer, Slit= 25um, Resolution: 0.05, Detection Range: 597-788nm
486-6850.190.25 In Stock Request for quote
PG4000-3C-680-1100
Ultra High Resolution Spectrometer, Slit= 25um, Resolution: 0.06, Detection Range: 395-602nm
680-11000.430.53 In Stock Request for quote
PG4000-5C-180-400
Ultra High Resolution Spectrometer, Slit= 25um, Resolution: 0.06, Detection Range: 180-400nm
180-4000.240.4 In Stock Request for quote

PG4000-5C-180-400 - Parameter

Wavelength (nm)
180-400

Dimension (mm)
157x115x41

25um Slit Optical Resolution (nm)
0.24

50um Slit Optical Resolution (nm)
0.4

Optical Resolution Tolerance (FWHM)
±20%

Dynamic Range
3000:1

Integration Time
4ms-60s

PG4000-3C-680-1100 - Parameter

Wavelength (nm)
680-1100

Dimension (mm)
157x115x41

25um Slit Optical Resolution (nm)
0.43

50um Slit Optical Resolution (nm)
0.53

Optical Resolution Tolerance (FWHM)
±20%

Dynamic Range
3000:1

Integration Time
4ms-60s

PG4000-3C-486-685 - Parameter

Wavelength (nm)
486-685

Dimension (mm)
157x115x41

25um Slit Optical Resolution (nm)
0.19

50um Slit Optical Resolution (nm)
0.25

Optical Resolution Tolerance (FWHM)
±20%

Dynamic Range
3000:1

Integration Time
4ms-60s

PG4000-3C-277-491 - Parameter

Wavelength (nm)
277-491

Dimension (mm)
157x115x41

25um Slit Optical Resolution (nm)
0.21

50um Slit Optical Resolution (nm)
0.25

Optical Resolution Tolerance (FWHM)
±20%

Dynamic Range
3000:1

Integration Time
4ms-60s

PG4000-5C-950-1100 - Parameter

Wavelength (nm)
950-1100

Dimension (mm)
157x115x41

25um Slit Optical Resolution (nm)
0.21

50um Slit Optical Resolution (nm)
0.35

Optical Resolution Tolerance (FWHM)
±20%

Dynamic Range
3000:1

Integration Time
4ms-60s

PG4000-5C-783-955 - Parameter

Wavelength (nm)
783-955

Dimension (mm)
157x115x41

25um Slit Optical Resolution (nm)
0.22

50um Slit Optical Resolution (nm)
0.38

Optical Resolution Tolerance (FWHM)
±20%

Dynamic Range
3000:1

Integration Time
4ms-60s

PG4000-5C-597-788 - Parameter

Wavelength (nm)
597-788

Dimension (mm)
157x115x41

25um Slit Optical Resolution (nm)
0.21

50um Slit Optical Resolution (nm)
0.39

Optical Resolution Tolerance (FWHM)
±20%

Dynamic Range
3000:1

Integration Time
4ms-60s

PG4000-5C-395-602 - Parameter

Wavelength (nm)
395-602

Dimension (mm)
157x115x41

25um Slit Optical Resolution (nm)
0.24

50um Slit Optical Resolution (nm)
0.39

Optical Resolution Tolerance (FWHM)
±20%

Dynamic Range
3000:1

Integration Time
4ms-60s

PG4000-5C-180-400 - Download

PG4000-3C-680-1100 - Download

PG4000-3C-486-685 - Download

PG4000-3C-277-491 - Download

PG4000-5C-950-1100 - Download

PG4000-5C-783-955 - Download

PG4000-5C-597-788 - Download

PG4000-5C-395-602 - Download

Accessories

Motorized Actuator Adapters

Compare Model Drawings & Specs Availability Price
(USD)